Abstract

Background
The performance of emerging transcatheter aortic valve implantation (TAVI) clinical prediction models (CPMs) in national TAVI cohorts distinct from those where they have been derived is unknown. This study aimed to investigate the performance of the German Aortic Valve, FRANCE-2, OBSERVANT and American College of Cardiology (ACC) TAVI CPMs compared with the performance of historic cardiac CPMs such as the EuroSCORE and STS-PROM, in a large national TAVI registry.

Methods
The calibration and discrimination of each CPM were analyzed in 6676 patients from the UK TAVI registry, as a whole cohort and across several subgroups. Strata included gender, diabetes status, access route, and valve type. Furthermore, the amount of agreement in risk classification between each of the considered CPMs was analyzed at an individual patient level.

Results
The observed 30-day mortality rate was 5.4%. In the whole cohort, the majority of CPMs over-estimated the risk of 30-day mortality, although the mean ACC score (5.2%) approximately matched the observed mortality rate. The areas under ROC curve were between 0.57 for OBSERVANT and 0.64 for ACC. Risk classification agreement was low across all models, with Fleiss's kappa values between 0.17 and 0.50.

Conclusions
Although the FRANCE-2 and ACC models outperformed all other CPMs, the performance of current TAVI-CPMs was low when applied to an independent cohort of TAVI patients. Hence, TAVI specific CPMs need to be derived outside populations previously used for model derivation, either by adapting existing CPMs or developing new risk scores in large national registries.

Item Type: Article
Additional Information: This is the accepted author manuscript (AAM). The final published version (version of record) is available online via Elsevier at http://dx.doi.org/10.1016/j.ahj.2016.10.020 Please refer to any applicable terms of use of the publisher.
Uncontrolled Keywords: aortic stenosis, transcatheter aortic valve implantation, mortality risk prediction, clinical prediction models
Subjects: R Medicine > R Medicine (General)
Divisions: Faculty of Medicine and Health Sciences > Institute for Science and Technology in Medicine
Depositing User: Symplectic
Date Deposited: 31 Oct 2016 10:48
Last Modified: 22 Jun 2018 10:47
URI: https://eprints.keele.ac.uk/id/eprint/2373

Actions (login required)

View Item
View Item