Real-world practice level data analysis confirms link between variability within Blood Glucose Monitoring Strip (BGMS) and glycosylated haemoglobin (HbA1c) in Type 1 Diabetes.

Heald, Adrian H.; Livingston, Mark; Fryer, Anthony; Cortes, Gabriela; Anderson, Simon G.; Gadsby, Roger; Laing, Ian; Lunt, Mark; Young, Robert J.; Stedman, Mike

Real-world practice level data analysis confirms link between variability within Blood Glucose Monitoring Strip (BGMS) and glycosylated haemoglobin (HbA1c) in Type 1 Diabetes. Thumbnail


Authors

Adrian H. Heald

Mark Livingston

Gabriela Cortes

Simon G. Anderson

Roger Gadsby

Ian Laing

Mark Lunt

Robert J. Young

Mike Stedman



Abstract

AIMS/HYPOTHESIS: Our aim was to quantify the impact of Blood Glucose Monitoring Strips variability (BGMSV) at GP practice level on the variability of reported glycated haemoglobin (HbA1cV) levels. METHODS: Overall GP Practice BGMSV and HbA1cV were calculated from the quantity of main types of BGMS being prescribed combined with the published accuracy, as % results within ±% bands from reference value for the selected strip type. The regression coefficient between the BGMSV and HbA1cV was calculated. To allow for the aggregation of estimated three tests/day over 13 weeks (ie, 300 samples) of actual Blood Glucose (BG) values up to the HbA1c, we multiplied HbA1cV coefficient by v300 to estimate an empirical value for impact of BGMSV on BGV. RESULTS: Four thousand five hundred and twenty-four practice years with 159 700 T1DM patient years where accuracy data were available for more than 80% of strips prescribed were included, with overall BGMSV 6.5% and HbA1c mean of 66.9 mmol/mol (8.3%) with variability of 13 mmol/mol equal to 19% of the mean. At a GP practice level, BGMSV and HbA1cV as % of mean HbA1c (in other words, the spread of HbA1c) were closely related with a regression coefficient of 0.176, P < 0.001. Thus, greater variability in the BGMS at a GP practice level resulted in a greater spread of HbA1C readings in T1DM patients. Applying this factor for BGMS to the national ISO accepted standard where 95% results must be =±15% from reference, revealed that for BG, 95% results would be =±45% from the reference value. Thus, the variation in BG is three times that of the BGMS. For a patient with BG target @10 mmol/L using the worst performing ISO standard strips, on 1/20 occasions (average 1/week) actual blood glucose value could be >±4.5 mmol/L from target, compared with the best performing BGMS with BG >±2.2 mmol/L from reference on 1/20 occasions. CONCLUSION: Use of more variable/less accurate BGMS is associated both theoretically and in practice with a larger variability in measured BG and HbA1c, with implications for patient confidence in their day-to-day monitoring experience.

Acceptance Date Jul 31, 2018
Publication Date Aug 31, 2018
Journal International Journal of Clinical Practice
Print ISSN 1368-5031
Publisher Wiley
Pages e13252 - ?
DOI https://doi.org/10.1111/ijcp.13252
Keywords Blood Glucose (D001786), Blood Glucose Self-Monitoring (D015190), Data Analysis, Diabetes Mellitus, Type 1 (D003922), General Practice (D058006), Glycated Hemoglobin A, Humans (D006801), Reference Values (D012016)